The Auto Cycle system is controlled by the splitter valve. The valve has two handles – one controls the cylinder extension, and the other controls the cylinder retraction. To operate the Auto Cycle function, move both levers into the detent position. The detent holds the handles in the open position and the cylinder extends.
When cylinder is fully extended, pressure buildup inside the extension section of the valve will kick the lever into neutral and send fluid to the retraction section to retract the cylinder. When the cylinder is fully retracted, pressure buildup inside the retraction section of the valve kicks the lever into neutral and the cylinder will stay in the retracted position until the valve is manually operated again.
The levers may be operated individually to extend or retract the cylinder without using the Auto Cycle function.
.